Heat Pump Glossary
Plain-English definitions of the technical terms you will encounter when comparing heat pump brands for your Scottish home.
- ASHP
- Air Source Heat Pump — extracts heat from outdoor air, even in sub-zero temperatures, to heat your home and hot water.
- COP
- Coefficient of Performance — the ratio of heat output to electricity input at a single measured temperature. A COP of 4 means 4kW of heat from 1kW of electricity.
- SCOP
- Seasonal Coefficient of Performance — the average COP across a full heating season. More useful than COP for comparing brands in Scotland's climate.
- Flow temperature
- The temperature of water sent to your radiators or underfloor heating. Lower flow temperatures (35-45°C) give higher efficiency.
- EPC
- Energy Performance Certificate — rates your home's energy efficiency from A (best) to G (worst). Required for government grant applications.
- MCS
- Microgeneration Certification Scheme — the UK quality standard for renewable energy installations. MCS certification is required for government grant eligibility.
- R290
- Propane refrigerant — a natural refrigerant with very low global warming potential (GWP of 3). Used in Vaillant aroTHERM plus.
- R32
- A synthetic refrigerant with moderate GWP (675). Used in Daikin Altherma, Mitsubishi Ecodan, and Samsung EHS.
- R410A
- An older synthetic refrigerant with high GWP (2088). Used in NIBE F2120. Being phased out under F-gas regulations.
- Buffer tank
- A small water tank that smooths heat pump operation, reducing start/stop cycles and improving efficiency. Not always required.
- Defrost cycle
- An automatic process where the heat pump briefly reverses to melt ice from the outdoor unit in cold weather. All brands handle this; it typically takes 2-5 minutes.
- Weather compensation
- A control feature that adjusts flow temperature based on outdoor temperature, maximising efficiency. Standard on all modern brands.
- Hybrid system
- A heat pump paired with an existing boiler. The boiler covers peak demand on the coldest days. Useful for properties where a full heat pump would be oversized.
- dB(A)
- Decibel measurement weighted for human hearing. Heat pump outdoor units typically range from 38-56 dB(A) at 1 metre — comparable to a fridge or quiet conversation.
- Legionella cycle
- A weekly automatic pasteurisation of the hot water cylinder to 60°C, killing harmful bacteria. All brands support this.
- TRV
- Thermostatic Radiator Valve — controls individual radiators. Important for zoning with heat pumps.